# Oscilloscope measurement record

ARGYNIX Skills (worldskills.blog), lesson "Oscilloscope measurements you can defend".
Our own template. One block per measurement. A reading without these settings cannot be
checked or repeated, so it earns little in a report.

## Instrument

| Item | Entry |
|---|---|
| Scope model and its bandwidth | (for example 100 MHz) |
| Its rise time, 0.35 / bandwidth | (100 MHz: 3.5 ns) |
| Probe model, attenuation (1x / 10x), probe setting on the scope matches? | |
| Probe compensated today? | yes / no |
| Ground connection | long lead / ground spring |

## Settings for this measurement

| Setting | Entry |
|---|---|
| Point on the circuit (net name, pin, test point) | |
| Volts per division | |
| Time per division | |
| Record length shown (10 x time per division) | |
| Sample rate shown on the screen | |
| Coupling (DC / AC) | |
| Trigger: source, edge, level | |
| Acquisition (normal / average of n / peak detect) | |
| Bandwidth limit on? | |

Check before you trust it: sample rate at least 4 to 5 times the fastest frequency you
care about, and at least 10 samples on every edge you time.

## Results

| Quantity | Design value | Measured | Method (automatic / cursors) | Difference (%) |
|---|---|---|---|---|
| Frequency | | | | |
| Period | | | | |
| HIGH time (+ width) | | | | |
| Duty cycle | | | | |
| Amplitude (top minus base) | | | | |
| Rise time, 10 % to 90 % | | | | |

Rise time, corrected for the scope: t_true = sqrt(t_measured squared - t_scope squared).
If t_measured is under about 1.5 times the scope's own rise time, report it as limited by
the scope, not as a value.

## Saved waveform

File name: ________________ (board, point, date, number). Scales, trigger and probe
setting visible in the picture: [ ]