Finding a short on a power rail

Find the one shorted part on a rail full of capacitors, by injecting a safe current and following the voltage drop, then prove it and record why it failed.

Lesson 1 of 345 minड्राफ़्ट

अनुवाद होने तक यह पाठ अंग्रेज़ी में है।

What the standard asks

Section 5, Fault finding, is worth 5% of the marks on its own (WorldSkills Occupational Standards, Electronics, WorldSkills Shanghai 2026, checked 2026-11-25). It asks you to plan a test strategy, use the right instrument for each measurement, and find the cause of a fault and the repair it needs. In practice it is worth far more, because a board that will not power up stops every module that uses it.

The section page shows the first steps: a rail that reads almost 0 Ω to ground means a short, and you lift parts until it goes. That works, but on a rail with twenty capacitors it can take an hour and damage good pads. This lesson finds the part in minutes, without lifting anything until you know which one it is.

The theory

Three kinds of rail fault

  • A hard short: under about 1 Ω from the rail to ground. A capacitor cracked through, a solder bridge, a part fitted backwards, a dead chip.
  • A soft short: tens or hundreds of ohms where a good board reads far more. Usually a damaged chip or a leaking part.
  • A rail that is low, not shorted: the regulator is the problem, not the load. More on that below.

Always measure both ways, red on the rail then black on the rail. Chips read differently each way because of their internal diodes. A good board's reading is the best reference: write it down for every board you build, so you have it when one fails.

Inject a current, safely

Copper has resistance. One square of 1 oz (35 µm) copper, any size, measures about 0.49 mΩ (copper's resistivity, 1.72 × 10⁻⁸ Ω·m, divided by the thickness). A track 0.3 mm wide and 30 mm long is 100 squares: about 49 mΩ. Tiny, but measurable when a real current flows.

So: drive a known current into the rail with a bench supply, and let the short carry it to ground. Then:

  • The supply voltage limit must be below the rail's normal voltage, so nothing is overvolted. If the rail has chips whose protection diodes could conduct, keep it under about 0.5 V.
  • The current limit sets the current: start at 0.5 A, then 1 A. The supply goes into constant current mode (CC) because the short pulls its voltage down.
  • Current flows only along the path from your injection point to the short. Beyond the short, no current flows, so no voltage drops.

Follow the drop

Put the meter on its lowest millivolt range (on a 200.0 mV range, 0.1 mV steps). Hold the black probe on the injection point and touch the red probe on each capacitor pad along the rail. The reading grows as you move toward the short, then stops growing once you pass it. Do the same on the ground side, black probe on ground at the injection point. The short is where both maps meet.

On a ground plane the drops are small: tens of microvolts to a few millivolts. If you see nothing, raise the current to 2 A if the parts and the board can take it, or use a meter with microvolt resolution.

Confirm with heat

The short turns the current into heat in one spot. After 30 to 60 seconds at 1 A, dab isopropyl alcohol on the area: it dries first on the hot part. A thermal camera, or freeze spray, shows the same. A fingertip held near the parts works too. Never touch a part that may be hot.

When the rail is low but not shorted

Before you hunt a short, check the regulator:

  • Dropout. A regulator needs its input above its output by a margin. A 7805 needs about 2 V more at its input (LM340 datasheet). With 6 V in, it cannot make 5.0 V.
  • Thermal shutdown. A 7805 dropping 12 V to 5 V at 300 mA turns (12 − 5) × 0.3 = 2.1 W into heat. A TO-220 in still air with no heatsink is typically somewhere around 50 to 65 °C per watt, so that is a rise of about 105 to 135 °C: enough for its own protection to cut the output. The clue: it works when cold and fails after a minute.
  • Oscillation. Some regulators need the right output capacitor to stay stable. A scope on the output shows ripple of hundreds of kilohertz where a meter shows only a low reading.
  • Enable pin off, or the regulator fitted backwards or wrong.

Worked example

A board with a 3.3 V rail from a low-dropout regulator, feeding a microcontroller and twelve 100 nF capacitors, C1 to C12, along the rail.

Symptom. Powered at 5 V from a bench supply with a 200 mA limit, the supply hits its limit at once and the 3.3 V rail reads 0.08 V.

  1. Power off. Measure. Rail to ground: 0.6 Ω both ways. The meter's leads touched together: 0.2 Ω. So the rail reads about 0.4 Ω: a hard short. A good board of the same design reads 1.4 kΩ.
  2. Inject. Supply set to 0.5 V and 1.0 A, connected to the regulator's output pad and ground. It goes into CC: 1.00 A at 0.41 V.
  3. Map the rail side, black probe on the injection point:
PointC1C3C5C8C10C11C12
Drop (mV)0.32.13.85.26.46.46.4

The drop rises up to C10, then stays the same. No current flows beyond C10, so the current leaves the rail at C10.

  1. Map the ground side. The readings grow toward C10 too. Both maps meet at C10.
  2. Check the numbers. 6.4 mV at 1 A is 6.4 mΩ of copper: about 13 squares of 1 oz copper, which matches a short, narrow track run. The numbers make sense, so trust them.
  3. Heat. After 40 seconds, alcohol dabbed across C9 to C11 dries first on C10.
  4. Remove C10. The rail now reads 1.4 kΩ to ground, the same as the good board. Under the loupe, C10 has a crack across one end.
  5. Ask why. C10 sits 2 mm from a mounting hole. When the board was screwed down hard, it flexed and cracked the capacitor. A new C10 would crack the same way.
  6. Repair and record. Fit a new capacitor, power up with the current limit: the rail is 3.30 V at 18 mA. Record: symptom, evidence (0.4 Ω, the mV map, the heat), cause (flex crack near the mounting hole), action (replaced C10, screw tightened by hand only, design note to move it), result.

Twelve minutes, and only one part touched.

Practice task

  1. On a working board with several capacitors on one rail, measure and write down the rail-to-ground reading both ways. That is your reference.
  2. Ask a partner to plant a short while you are out of the room: a solder bridge across one capacitor, or a short wire under a part.
  3. Find it with current injection and a millivolt map, using the downloadable sheet. Lift nothing until you have named the part.
  4. Time yourself. Target: under 15 minutes from symptom to named part.
  5. Swap roles. Then repeat with a soft short: a 47 Ω resistor across a capacitor. What changes in your method?

Common mistakes

  • Lifting parts one by one. Slow, and every lift risks a pad. Find it first, then lift one part.
  • A voltage limit above the rail's normal voltage. You can overvolt the healthy parts while hunting the faulty one.
  • Forgetting the meter leads' own resistance. On a 0.4 Ω short, 0.2 Ω of leads is half the reading.
  • Measuring the drop on the wrong range. On a 20 V range, 6.4 mV reads as 0.00. Use the lowest mV range.
  • Mapping only the rail side. The ground side confirms the place, and sometimes the rail map alone points to a long track, not the part.
  • Replacing the part and stopping. If you do not find why it failed, the new one fails the same way.
  • Hunting a short when the regulator is the fault. Check dropout, heat and enable before you inject anything.

Self-check

  1. A rail reads 0.5 Ω to ground and the meter's leads alone read 0.2 Ω. What is the rail's real resistance, and is it a hard or a soft short?
  2. Why must the injection supply's voltage limit be below the rail's normal voltage?
  3. In the millivolt map, the drop rises from point to point and then stays the same. What does that tell you?
  4. What is the resistance of a 1 oz copper track 0.5 mm wide and 20 mm long, roughly?
  5. A 7805 board works for one minute, then its output falls. Give the likely cause and one check.
  6. You found and replaced a cracked capacitor. Why is the job not finished?
Show answers
  1. About 0.3 Ω, a hard short: the leads' 0.2 Ω must be subtracted, and anything under about 1 Ω is a hard short.
  2. So no healthy part on the rail sees more than its normal voltage. Below about 0.5 V, chips' protection diodes do not conduct either, so all the current goes through the short.
  3. The current leaves the rail where the drop stops rising. Beyond the short no current flows, so there is no more voltage drop.
  4. 20 ÷ 0.5 = 40 squares, × 0.49 mΩ ≈ 20 mΩ. At 1 A it drops about 20 mV.
  5. Thermal shutdown: the regulator turns too much power into heat. Check the power, (Vin − Vout) × I, against what the package can lose, and feel near it or measure its temperature when it cuts out.
  6. Because you have not found why it cracked. A part near a mounting hole, an overtightened screw or a dropped board will crack the new one too. The cause, and what you did about it, go in the record.

Downloads

  • short-hunt-sheet.md: our fault-finding sheet for a shorted rail: readings, injection settings, the millivolt map table and the record.

Practise in ARGYNIX Lab

Nothing in this lesson runs in ARGYNIX Lab: it does not model the resistance of copper, so a millivolt map has nothing to measure. Practise at the bench with a partner who plants the shorts. Keep a sheet for every board you build, with its normal rail readings, so that when one fails you have a reference ready.