This section is worth 15% of the marks. A measurement is only useful if someone else can trust it and repeat it. That means the right instrument, the right settings, the right unit, an honest idea of how accurate it is, and a clear report.
What the standard asks
You will need to:
- Know the tools and software used for documents and reports.
- Know how calculations and measurements are checked, and the usual formats for reporting them.
- Know what makes a measurement good quality.
- Know what to put in a report, and how to structure and present it for different purposes.
- Prepare detailed drawings and specifications from an engineer's instructions.
- Draw schematics with schematic capture and PCB design software.
- Produce drawings with CAD software (computer-aided design) for industrial control, instruments, sensors and communication networks.
- Write reports in suitable formats, such as PDF, word processor and spreadsheet files, for fault finding, modifications, measurements and component choice.
- Record the calculation for each component and quantity, with units.
- Record each measurement next to its design value, for example amplitude, frequency, duty cycle or cutoff frequency.
- Record each successful repair: the fault, the evidence, the cause and what you did.
- Complete digital reports with all the data asked for, including calculations, waveforms and symbols.
- Write clear design reports that compare designs and include simulation results and a risk analysis.
Why it matters on the competition floor
Reports are marked on whether the numbers are right, and on whether they are complete and clear. A correct reading with no unit, no instrument setting or no design value to compare with is weak evidence. A waveform screenshot without its scale is just a picture.
Reports are also where tired competitors lose easy marks at the end of a day. Record as you go. Never write a report from memory.
Topics, from Foundation to World
- Foundation. Units, prefixes, significant figures and rounding.
- Foundation. Multimeter technique: choosing the range, reading the accuracy specification, and avoiding loading the circuit.
- Foundation. Oscilloscope measurements: amplitude, peak-to-peak voltage, period, frequency, duty cycle and rise time, with cursors and with automatic measurements.
- State. Measurement quality: accuracy, resolution and uncertainty (how far from the true value your reading could be).
- State. A results table: design value, measured value and the difference in percent.
- State. Saving waveforms with their settings visible, and labelling them.
- State. Report types: measurement, fault finding, modification and component selection.
- National. Frequency response: gain in decibels (dB) and finding the cutoff frequency.
- National. Drawings and specifications from instructions: block diagrams, schematics, wiring diagrams and simple mechanical drawings.
- National. Spreadsheets for calculations and graphs.
- World. Design reports: comparing options, simulation against measurement, and risk analysis.
- World. Sources of error: probe loading, bandwidth limits, ground loops and temperature, and stating your uncertainty.
Key ideas to master
Accuracy and resolution are different. Resolution is the smallest step the display can show. Accuracy is how close the reading is to the true value. A meter can show 12.003 V and still be wrong by 0.1 V.
Use the specification. A meter's accuracy is often written as ±(% of reading + digits). "Digits" means steps of the last digit on the display.
Worked example: on its 20.00 V range, a meter's specification is ±(0.5 % + 2 digits). It reads 12.00 V.
- 0.5 % of 12.00 V = 0.06 V
- 2 digits on this range = 2 × 0.01 V = 0.02 V
- Total: ±0.08 V. Write the result as 12.00 V ± 0.08 V. The true value is between 11.92 V and 12.08 V.
Do not write more digits than you can trust. If your uncertainty is ±0.08 V, writing 12.0347 V is not more accurate. It is just misleading.
Compare with the design. Percent difference = (measured − design) ÷ design × 100 %.
Worked example: you designed an RC filter for a cutoff of 1.59 kHz. You measure 1.52 kHz. Difference = (1.52 − 1.59) ÷ 1.59 × 100 % ≈ −4.4 %. Then explain it: the capacitor has a tolerance of ±10 %, so this difference is expected. That explanation is what turns numbers into a report.
Duty cycle and frequency. Duty cycle = high time ÷ period × 100 %. Frequency = 1 ÷ period. A signal high for 0.25 ms in every 1 ms has a frequency of 1 kHz and a duty cycle of 25 %.
Decibels and the cutoff frequency. Gain in dB = 20 × log10(Vout ÷ Vin). At the cutoff frequency of a simple filter, the output is about 0.707 of the input in its passband. That is −3 dB.
Know the scope's limits. At its rated bandwidth, a scope already shows a sine wave about 30 % smaller than it really is (−3 dB). So choose a scope with a bandwidth several times higher than the signal you measure. A useful estimate of the fastest rise time a scope can show is 0.35 ÷ bandwidth: about 3.5 ns for a 100 MHz scope.
Check automatic measurements. Automatic scope measurements need a clean signal and enough cycles on the screen. Check important ones with the cursors.
Save waveforms properly. Every saved waveform should show the volts per division, the time per division, the trigger setting and the probe setting. Give it a title and say where on the circuit it was measured.
A report structure that works.
- Title, date, your name or competitor number, and the board and version.
- Purpose: what you were asked to find or prove.
- Equipment: each instrument's model and the settings you used.
- Method: what you did, in short steps.
- Results: a table of design value, measured value, unit and difference, with waveforms.
- Calculations: the formula, the numbers put in, and the answer with its unit.
- Discussion: why the results differ from the design.
- Conclusion: one or two sentences that answer the purpose.
A repair record has five parts: the symptom, the evidence (what you measured), the cause, the action you took, and the result when you tested again.
Risk analysis in a design report. List what could go wrong (a part overheats, a part is hard to buy, noise upsets the sensor), how likely it is, how bad it would be, and what you did about it.
Practise with cheap equipment
- Ten resistors. Measure 10 resistors. Make a table: marked value, measured value, tolerance, and whether each one is within tolerance.
- Filter sweep. Build an RC filter. Measure the output at 10 frequencies with a signal generator and a scope. Plot gain in dB against frequency in a spreadsheet. Find the −3 dB point and compare it with your calculation and your simulation.
- PWM check. Make a microcontroller output PWM. Measure its frequency and duty cycle with cursors and with automatic measurements. Compare both with the values in your code.
- Report after every fault. After each fault-finding practice, write a one-page repair record.
- Swap test. Swap reports with a friend. Can they repeat your measurement using only your report?
- Draw a system. Draw a block diagram and a wiring diagram for a small system, such as a sensor, a microcontroller and a display, in Autodesk Fusion's schematic editor.
Common mistakes
- Missing units, or the wrong prefix.
- More digits than the instrument can support.
- Waveforms saved without their scale settings, or with no label.
- A 1x probe used with the scope set to 10x, so every reading is ten times wrong.
- No record of which instrument and settings were used.
- Only answers shown, with no formula or working.
- The report left until the end, then written from memory.
How this section is marked
ARGYNIX practice marking guide, written by us; not the official WorldSkills marking scheme. The official marking scheme belongs to WorldSkills and is set for each competition. We do not copy it, and we do not claim to know it. Use this guide to mark your own practice work. For how a skill is marked in general, read how a skill is marked. For what this section covers, read the official standard (opens in a new tab).
Where its marks come from. Its marks usually come from the reports and drawings you hand in, and from measurements you make and record during other modules being checked.
Measurement marks. These check facts: the right value within its tolerance, a unit on every number, a formula shown with its working, a waveform saved with its settings.
Judgement marks. These look at the report as a whole: whether it is clear, complete and easy to follow, and whether the discussion really explains the results.
A practice checklist. Mark a measurement report on a circuit you built, such as an RC filter or a small power supply. The checklist below is out of 15 marks.
| # | Aspect | Type | Marks |
|---|---|---|---|
| 1 | The instrument and its settings recorded for each measurement | M | 1 |
| 2 | Every reading has its unit and a sensible number of digits | M | 1 |
| 3 | Uncertainty stated, worked out from the instrument's specification | M | 1 |
| 4 | A table of design value, measured value and difference in percent | M | 2 |
| 5 | Each calculation shows the formula, the numbers and the answer with its unit | M | 2 |
| 6 | Measured values inside the range the parts' tolerances allow | M | 2 |
| 7 | Waveforms saved with the scale, trigger and probe settings visible | M | 1 |
| 8 | Each waveform titled with where on the circuit it was measured | M | 1 |
| 9 | The discussion explains every difference from the design | J | 2 |
| 10 | A clear structure, and a conclusion that answers the purpose | J | 2 |
| Total | 15 |
Mark your own work. Give a measurement (M) aspect its full marks or nothing: it was done or it was not. Score a judgement (J) aspect from 0 to 3, the way Experts do: 0 is below industry standard, 1 meets it, 2 is better than it, and 3 is excellent. Then take that share of its marks: a score of 2 on a 1.5-mark aspect earns 1 mark.
Use your score. Give your report to a friend with no other help. If they cannot repeat your measurement from it, the report is not finished. Mark the same kind of task every two weeks and write the score in your training log.
Check yourself
- A meter's specification is ±(1 % + 3 digits). On the 2.000 V range it reads 1.500 V. What is the uncertainty?
- A square wave is high for 2 ms and low for 6 ms. What are its frequency and duty cycle?
- The input is 2.0 V peak-to-peak and the output is 1.0 V peak-to-peak. What is the gain in dB?
- You designed for 1.00 kHz and measured 1.07 kHz. What is the percent difference?
- Name the five parts of a repair record.
Show answers
- 1 % of 1.500 V = 0.015 V. 3 digits = 3 × 0.001 V = 0.003 V. Total: ±0.018 V.
- The period is 8 ms, so the frequency is 1 ÷ 0.008 s = 125 Hz. The duty cycle is 2 ÷ 8 = 25 %.
- 20 × log10(1.0 ÷ 2.0) ≈ −6.0 dB.
- (1.07 − 1.00) ÷ 1.00 × 100 % = +7 %.
- Symptom, evidence, cause, action, and the result of the test after the repair.
Materials
Equipment
- A digital multimeter, and its manual: you need its accuracy specification.
- In the lab: an oscilloscope with 10x probes and a signal generator.
- A USB stick, to save waveforms from the scope.
Software
- A spreadsheet, for tables, calculations and graphs.
- A word processor that can save a PDF.
- Autodesk Fusion, for schematics and drawings. EAGLE if your competition provides it. The toolkit explains the free Education licence.
- LTspice, to compare a simulation with your measurements.
Printable checklist: before you hand in a report
- Title, date, name or number, board and version.
- Equipment listed with the settings used.
- Every number has its unit.
- A table of design, measured and difference.
- Every formula shown with its working.
- Every waveform shows its scales and says where it was measured.
- The conclusion answers the purpose in one or two sentences.
Print this page to take this checklist, the practice marking checklist and the self-check to your bench.
Free resources
- NIST Technical Note 1297 (opens in a new tab): a short official guide to working out and stating measurement uncertainty.
- JCGM publications, BIPM (opens in a new tab): the free international guides to uncertainty (the GUM) and to measurement words. World level.
- Guide for the Use of the SI (Special Publication 811), NIST (opens in a new tab): how to write values and units correctly.
- How to Use an Oscilloscope, SparkFun (opens in a new tab): settings and measurements for beginners.
- Introduction to Electronics, Signals, and Measurement (6.071J), MIT OpenCourseWare (opens in a new tab): a free course joining circuits and measurement.
- Introductory Analog Electronics Laboratory (6.101), MIT OpenCourseWare (opens in a new tab): lab work with real measurements and write-ups.
- Professional, technical writing, Purdue Online Writing Lab (opens in a new tab): how to write clear reports.
Lessons in this section
Each lesson goes further than this page, with a worked example, a practice task and a self-check. Take them in order.
0 of 3 lessons done
From reading to result: an uncertainty budget
Turn repeated readings and an instrument's specification into a result with an honest uncertainty: Type A and Type B, combining, coverage and rounding, in a budget you can defend.
50 minOscilloscope measurements you can defend
Set up the probe, the sample rate and the trigger so a scope reading is right, then measure frequency, duty, amplitude and rise time, and know how far to trust each number.
55 minMeasure a filter's frequency response and write the report
Sweep an RC low-pass filter, find its cutoff two independent ways, explain the difference from the design with numbers, and write a two-page report that someone else can repeat.
1 h